18
TM 5-3805-293-23-2
FIELD MAINTENANCE
-
0042
Test 1 Negative Battery Cable, Test 2 Positive Battery Cable, Test 3 Exterior Arctic Heater Battery Cables
INITIAL SETUP
References
Tools and Special Tools
0
0
Tool Kit, General Mechanic's
WP 0066
0
(WP 0354, Item 83)
WP 0195
0
0
Digital Multimeter (S0252)
WP 0337
0
(WP 0354, Item 85)
WP 0338
0
0
Materials/Parts
Equipment Condition
0
0
Rag, Wiping (WP 0355, Item 25)
Machine parked (TM 5-3805-293-10)
0
0
Personnel Required
Estimated Time to Complete
0
0
Two
2.0 Hr
0
0
TEST 1 NEGATIVE BATTERY CABLE
00042
1. Verify all battery cable connections are clean and tight.
2. Turn battery disconnect switch to the ON position (TM 5-3805-293-10).
3. Using a digital multimeter, measure voltage between positive post (Figure 1, Item 3), and negative (Figure 1,
Item 1) post of the machine batteries. Monitor and record voltage.
4. Using a digital multimeter, measure voltage between positive post (Figure 1, Item 3) of machine battery and
machine ground (Figure 1, Item 2). Voltage should not be less than 1 volt of value recorded in step 3.
a. If voltage is equal to value recorded in step 3, proceed to step 5.
b. If voltage is less than 1 volt of value recorded in step 3, machine negative battery cables OK, proceed to
Test 2.
Figure 1. Positive and Negative Battery Voltage Test.
0042