Figure 2. Ammeter Connection.
BATTERY TEST AND BATTERY CHARGING

Maintenance Manual For Motorized Road Grader Model 120M - 2
Page Navigation
  1248    1249    1250    1251    1252  1253  1254    1255    1256    1257    1258  
img
.
TM 5-3805-293-23-2
0040
7. Remove ammeter from machine.
8. Place multimeter positive lead on B+ terminal (Figure 3, Item 3) of alternator (Figure 3, Item 2).
9. Place multimeter negative lead on negative terminal (Figure 3, Item 1) of alternator (Figure 3, Item 2).
10. With engine still running, monitor digital multimeter. Voltage reading should be 24-28 volts.
a. If voltage is within specified range, alternator and charging system are OK.
b. If voltage is less than 24 volts or more than 28 volts, then the alternator is faulty. Replace alternator (WP
0094).
Figure 3. Alternator.
0040
END OF TASK
END OF WORK PACKAGE