Figure 3. Alternator.
BATTERY CHARGING OUT OF MACHINE

Maintenance Manual For Motorized Road Grader Model 120M - 2
Page Navigation
  1249    1250    1251    1252    1253  1254  1255    1256    1257    1258    1259  
img
.
4
TM 5-3805-293-23-2
0041
FIELD MAINTENANCE
-
BATTERY TEST AND BATTERY CHARGING
0041
Battery Test, Battery Charging Out of Machine, Battery Charging with NATO Slave Receptacle
INITIAL SETUP
Tools and Special Tools
References
0
0
Tool Kit, General Mechanic's
WP 0192
0
(WP 0354, Item 83)
WP 0194
0
0
Battery Analyzer (WP 0354, Item 85)
WP 0334
0
0
Battery Charger (WP 0354, Item 85)
0
Equipment Condition
0
Battery Terminal Cleaner (S0136)
Machine parked (TM 5-3805-293-10)
(WP 0354, Item 85)
0
0
Estimated Time to Complete
Materials/Parts
0
0
1.0 Hr
Rag, Wiping (WP 0355, Item 25)
0
0
Personnel Required
0
Two
0
BATTERY TEST
00041
1. Turn ignition switch and battery disconnect switch to the OFF position (TM 5-3805-293-10).
2. Disconnect battery cables from each battery (WP 0194).
3. If equipped with arctic heater, disconnect battery cables from each arctic heater battery (WP 0334).
4. Clean battery post using battery terminal cleaner.
5. Using battery analyzer, test each battery.
a. Battery analyzer displays GOOD BATTERY - Battery is OK.
b. Battery analyzer displays GOOD RECHARGE - Charge battery; refer to Battery Charging in this work
package. Test battery using battery analyzer. If battery analyzer displays GOOD RECHARGE again,
replace battery (WP 0194, WP 0334).
c.
Battery analyzer displays CHARGE & RETEST - Charge battery; refer to Battery Charging in this work
package. Test battery using battery analyzer. If battery analyzer displays CHARGE & RETEST again,
replace battery (WP 0194, WP 0334).
d. Battery analyzer displays REPLACE BATTERY - Battery failed test; replace battery (WP 0194, WP 0334).
END OF TASK