Figure 4. Arctic Heater Negative Battery Cable Junction.
Figure 6. Alternator Negative Cable.

Maintenance Manual For Motorized Road Grader Model 120M - 2
Page Navigation
  1256    1257    1258    1259    1260  1261  1262    1263    1264    1265    1266  
img
.
TM 5-3805-293-23-2
0042
TEST 1 NEGATIVE BATTERY CABLE CONTINUED
00042
9. Release two latches (Figure 5, Item 5) on arctic heater battery cover (Figure 5, Item 1).
10. With an assistant, remove arctic heater battery cover (Figure 5, Item 1) from machine.
11. Using digital multimeter, measure voltage between positive post (Figure 5, Item 4) of machine battery and
negative post (Figure 5, Item 2) of arctic heater battery (Figure 5, Item 3). Voltage should not be less than 1
volt of value recorded in step 3.
a. If voltage is less than 1 volt of value recorded in step 3, replace exterior arctic heater negative battery
cable (WP 0337). End of Task.
b. If voltage is equal to value recorded in step 3, with an assistant, install arctic heater battery cover (Figure
5, Item 1) and set two latches (Figure 5, Item 5). Proceed to step 12.
Figure 5. Arctic Heater Negative Battery Cable.
0042
0042-5