BATTERY CABLES AND ALTERNATOR CABLES TEST
Figure 3. Negative Contact of NATO Slave Receptacle.

Maintenance Manual For Motorized Road Grader Model 120M - 2
Page Navigation
  1253    1254    1255    1256    1257  1258  1259    1260    1261    1262    1263  
img
.
TM 5-3805-293-23-2
0042
TEST 1 NEGATIVE BATTERY CABLE CONTINUED
00042
5. Using digital multimeter, measure voltage between positive post (Figure 2, Item 2) of machine battery and
negative battery cable junction (Figure 2, Item 1). Voltage should not be less than 1 volt of value recorded in
step 3.
a. If voltage is less than 1 volt of value recorded in step 3, replace negative battery cable (WP 0195). End of
Task.
b. If voltage is equal to value recorded in step 3, proceed to step 6.
Figure 2. Negative Battery Cable Junction.
0042