TM 5-3805-293-23-2
0042
TEST 1 NEGATIVE BATTERY CABLE CONTINUED
00042
6. Remove cover (Figure 3, Item 3) from NATO slave receptacle (Figure 3, Item 1).
7. Using digital multimeter, measure voltage between positive post (Figure 3, Item 4) of machine battery and
outer contact (Figure 3, Item 2) (negative side) of NATO slave receptacle (Figure 3, Item 1). Voltage should not
be less than 1 volt of value recorded in step 3.
a. If voltage is less than 1 volt of value recorded in step 3, replace negative battery cable (WP 0195). End of
Task.
b. If voltage is equal to value recorded in step 3, install NATO slave receptacle cover (Figure 3, Item 3) and
proceed to step 8.
Figure 3. Negative Contact of NATO Slave Receptacle.
0042