Figure 5. Arctic Heater Negative Battery Cable.
Figure 7. Positive and Negative Battery Voltage Test.

Maintenance Manual For Motorized Road Grader Model 120M - 2
Page Navigation
  1257    1258    1259    1260    1261  1262  1263    1264    1265    1266    1267  
img
.
TM 5-3805-293-23-2
0042
TEST 1 NEGATIVE BATTERY CABLE CONTINUED
00042
12. Using digital multimeter, measure voltage between positive post (Figure 6, Item 2) of machine battery and
negative terminal of alternator (Figure 6, Item 1). Voltage should not be less than 1 volt of value recorded in
step 3.
a. If voltage is less than 1 volt of value recorded in step 3, replace negative alternator cable (WP 0066). End
of Task.
b. If voltage is equal to value recorded in step 3, negative alternator and negative battery cables are OK.
Proceed to Test 2.
Figure 6. Alternator Negative Cable.
0042
END OF TASK