BATTERY CHARGING OUT OF MACHINE
BATTERY CABLES AND ALTERNATOR CABLES TEST

Maintenance Manual For Motorized Road Grader Model 120M - 2
Page Navigation
  1251    1252    1253    1254    1255  1256  1257    1258    1259    1260    1261  
img
TM 5-3805-293-23-2
0041
BATTERY CHARGING WITH NATO SLAVE RECEPTACLE
00041
1. Perform Battery Test, in this work package, on each battery to ensure all batteries are charged within 0.5 Volt
DC and 200 CCA (Cold Cranking Amps).
2. Turn battery charger switch OFF.
WARN I N G
Turn battery disconnect switch to OFF before installing NATO receptacle. Failure to follow
this warning may result in injury or death to personnel or damage to equipment.
3. Turn battery disconnect switch to OFF.
4. Connect battery cables to batteries (WP 0194).
5. If equipped with arctic heater, connect battery cables to each arctic battery (WP 0334).
6. Connect NATO slave jack on battery charger to the NATO slave receptacle (WP 0192).
7. Connect red and black charger cables to battery charger.
N OT E
Ensure battery charger switch is OFF before connecting the battery charger power cord.
8. Connect the battery charger power cord to battery charger.
9. Turn battery disconnect switch to ON.
10. Turn battery charger switch ON.
11. Charge battery until the green Charge Complete LED is illuminated.
12. Battery charger will terminate when charge current drops below 1 ampere.
13. When charge is complete, turn battery charger switch OFF.
14. Turn battery disconnect switch to OFF.
15. Remove NATO slave jack on battery charger from NATO slave receptacle (WP 0192).
END OF TASK
END OF WORK PACKAGE
0041-3/(4 blank)