TM 5-3805-293-23-2
0027
Table 1. Implement Code (0615-02 TO 2113-04) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
0650-02 Implement 2 ECM
Harness Code Data Erratic,
continuity between harness con-
wiring harness (WP 0188).
Intermittent or Incorrect
nector FA-C20 (WP 0009, Figure
Connect cab lower wiring harness
Data - Continued
113) terminal 20 and all other ter-
connector P-C93 (WP 0009, Figure
minals on harness connector FA-
163) to messenger (WP 0009, Figure
C20.
164) (WP 0272)
There should be no continuity.
Proceed to step 9.
transmission ECM (WP 0137) and
messenger (WP 0272).
Connect harness connector FA-C22
(WP 0009, Figure 47) to harness
connector P-C69 (WP 0009, Figure
46) (WP 0188).
Proceed to step 9.
9. Using MSD (WP 0006), select
0650-02 Code Remains Active -
Implement Control #2 and verify
Repeat troubleshooting from the
0650-02 is not active.
beginning of this diagnostic code.
0650-02 Code Not Active -
Troubleshooting complete.
System Response:
0967-02 Machine Applica-
tion Data Erratic, Intermit-
ECM will log a diagnostic code.
tent or Incorrect Data
N OT E
Always inspect the harness connectorsthat are involved in the circuit.
Poor connections can often be the cause of a problem in an electrical
circuit. Verify that all connections in the circuit are clean and secure,
and that all connections are in good condition. If a problem with a con-
nection is found, correct the problem and verify that this diagnostic code
is Active before performing this procedure.
Perform open or short circuit test ateach harness connection to identify
correct harness to replace.
Perform this test only if condition is active.
Test Step 1. Verify if Code 0967-02
is Active.
1. Connect MSD (WP 0006), select 0967-02 Code Active - Proceed to
Implement 120M and verify 0967- step 2.
02 is active.
0967-02 Code Not Active -
Troubleshooting complete.
2. Program the implement 1 ECM
and the Messenger (WP 0008).
0027-39