Table 1. Implement Code (0615-02 TO 2113-04) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
1326-02 Implement 1 ECM
Resistance 5.0 Ohms or Less -
Location Code Data Erratic,
Proceed to step 6.
Intermittent or Incorrect -
nector P-C41 (WP 0009, Figure
Continued
68) terminal 27 and machine
Proceed to Test Step 3.
ground.
Resistance should be less than
5.0 ohms.
Resistance 5.0 Ohms or Less -
Proceed to step 7.
nector P-C41 (WP 0009, Figure
68) terminal 32 and machine
Proceed to Test Step 3.
ground.
Resistance should be less than
5.0 ohms.
Resistance 5.0 Ohms or Less -
Proceed to step 8.
nector P-C41 (WP 0009, Figure
68) terminal 56 and machine
Proceed to Test Step 3.
ground.
Resistance should be less than
5.0 ohms.
Resistance 5.0 Ohms or Less -
Proceed to step 9.
nector P-C41 (WP 0009, Figure
68) terminal 57 and machine
Proceed to Test Step 3.
ground.
Resistance should be less than
5.0 ohms.
Resistance 5.0 Ohms or Less -
Proceed to step 10.
nector P-C41 (WP 0009, Figure
68) terminal 70 and machine
Proceed to Test Step 3.
ground.
Resistance should be less than
5.0 ohms.
10. Program implement 1 ECM (WP
0008).
11. Using MSD (WP 0006), select
1326-02 Code Remains Active -
Implement 120M and verify 1326- Replace implement 1 ECM (WP
02 is not active.
0268).
Proceed to step 12.
1326-02 Code Not Active -
Troubleshooting complete.