Table 1. Implement Code (0615-02 TO 2113-04) Troubleshooting Procedures - Continued.
Table 1. Implement Code (0615-02 TO 2113-04) Troubleshooting Procedures - Continued.

Maintenance Manual For Motorized Road Grader Model 120M - 2
Page Navigation
  592    593    594    595    596  597  598    599    600    601    602  
img
TM 5-3805-293-23-2
0027
Table 1. Implement Code (0615-02 TO 2113-04) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
1326-02 Implement 1 ECM
System Response:
Location Code Data Erratic,
ECM will log a diagnostic code.
Intermittent or Incorrect
N OT E
Always inspect the harness connectorsthat are involved in the circuit.
Poor connections can often be the cause of a problem in an electrical
circuit. Verify that all connections in the circuit are clean and secure,
and that all connections are in good condition. If a problem with a con-
nection is found, correct the problem and verify that this diagnostic code
is Active before performing this procedure.
Perform open or short circuit test ateach harness connection to identify
correct harness to replace.
Perform this test only if condition is active.
Test Step 1. Verify if Code 1326-02
is Active.
Connect MSD (WP 0006), select
1326-02 Code Active - Proceed to
Implement 120M and verify 1326-02
Test 2.
is active.
1326-02 Code Not Active -
Troubleshooting complete.
Test Step 2. Test Cab Lower Har-
ness Ground Circuits.
1. Turn ignition switch and battery
disconnect switch to the OFF
position (TM 5-3805-293-10).
2. Disconnect cab lower wiring har-
ness connector P-C41 (WP 0009,
Figure 68) from implement 1 ECM
(WP 0009, Figure 69) (WP 0268).
3. Using digital multimeter, test for
Resistance 5.0 Ohms or Less -
continuity between harness con-
Proceed to step 4.
nector P-C41 (WP 0009, Figure
Resistance More Than 5.0 Ohms -
68) terminal 13 and machine
Proceed to Test Step 3.
ground.
Resistance should be less than
5.0 ohms.
4. Using digital multimeter, test for
Resistance 5.0 Ohms or Less -
continuity between harness con-
Proceed to step 5.
nector P-C41 (WP 0009, Figure
Resistance Less Than 5.0 Ohms -
68) terminal 23 and machine
Proceed to Test Step 3.
ground.
Resistance should be less than
5.0 ohms.
0027-42