TM 5-3805-293-23-2
0027
Table 1. Implement Code (0615-02 TO 2113-04) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
0967-09 Machine Applica-
Voltage OK - Proceed to step 6.
tion Abnormal Update Rate -
voltage between harness connec-
Voltage Less Than 18 Volts -
Continued
tor P-C93 (WP 0009, Figure 163)
Replace cab lower wiring harness
terminal 3 and machine ground.
(WP 0266).
Voltage should be 18 to 26 volts.
Proceed to step 8.
6. Turn ignition switch and battery
disconnect switch to the OFF
position (TM 5-3805-293-10).
Resistance 5.0 Ohms or Less -
Proceed to Test Step 3.
nector P-C93 (WP 0009, Figure
163) terminal 2 and machine
Replace cab lower wiring harness
ground.
(WP 0266).
Resistance should be less than
Proceed to step 8.
5.0 ohms.
8. Using MSD (WP 0006), select
0967-09 Code Remains Active -
Implement 120M and verify 0967- Repeat troubleshooting from the
09 is not active.
beginning of this diagnostic code.
0967-09 Code Not Active -
Troubleshooting complete.
Test Step 3. Test Data Link Circuit.
1. Disconnect harness connector P-
C41 (WP 0009, Figure 68) from
implement 1 ECM J1 (WP 0009,
Figure 69) (WP 0268).
2. Install a jumper wire between har-
ness connector P-C93 (WP 0009,
Figure 163) terminal 5 and termi-
nal 6.
Resistance 5.0 Ohms or Less -
Replace messenger (WP 0272) and
nector P-C41 (WP 0009, Figure
implement 1 ECM (WP 0268).
68) terminal 10 and terminal 20.
Proceed to step 4.
Resistance should be less than
5.0 ohms.
Replace cab lower wiring harness
(WP 0266).
Proceed to step 4.
4. Using MSD (WP 0006), select
0967-09 Code Remains Active -
Implement 120M and verify 0967- Repeat troubleshooting from the
09 is not active.
beginning of this diagnostic code.
0967-09 Code Not Active -
Troubleshooting complete.