TM 5-3805-293-23-2
0027
Table 1. Implement Code (0615-02 TO 2113-04) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
0615-13 Machine Articula-
Test Step 3. Check Sensor.
tion Angle Sensor Out Of
1. Verify articulation angle position
Articulation Angle Position Sensor
Calibration - Continued
sensor 1 (left) is within specifica-
OK - Proceed to Test Step 4.
tions refer to Adjustment in WP
Articulation Angle Position Sensor
0257.
Needs Adjustment - Adjust sensor
as directed (WP 0257).
Proceed to step 2.
2. Using MSD (WP 0006), select
0615-13 Code Active - Repeat
Trans/Chassis 120M and verify
troubleshooting from the beginning of
0615-13 is active.
this diagnostic code.
0615-13 Code Not Active -
Troubleshooting complete.
Test Step 4. Calibrate Sensor.
1. Calibrate articulation angle posi-
Articulation Angle Position Sensor
Cannot Be Calibrated - Perform
WP 0257.
cannot be calibrated, replace
articulation angle position sensor (WP
0257).
Proceed to step 2.
Articulation Angle Position Sensor
Calibrated OK - Proceed to step 2.
0615-13 Code Active - Repeat
2. Using MSD (WP 0006), select
troubleshooting from the beginning of
Trans/Chassis 120M and verify
this diagnostic code.
0615-13 is active.
0615-13 Code Not Active -
Troubleshooting complete.
0615-14 Machine Articula-
System Response:
tion Angle Sensor Special
ECM will log a diagnostic code.
Instruction
N OT E
Always inspect the harness connectorsthat are involved in the circuit.
Poor connections can often be the cause of a problem in an electrical
circuit. Verify that all connections in the circuit are clean and secure,
and that all connections are in good condition. If a problem with a con-
nection is found, correct the problem and verify that this diagnostic code
is Active before performing this procedure.
Perform open or short circuit test ateach harness connection to identify
correct harness to replace.
Perform this test only if condition is active.
0027-34