TM 5-3805-293-23-2
0026
Table 1. Implement Code (0041-03 to 0600-04) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
0358-03 Implement Pilot
System Response:
Pressure Supply Solenoid
ECM will log a diagnostic code.
Voltage Above Normal
N OT E
Always inspect the harness connectorsthat are involved in the circuit.
Poor connections can often be the cause of a problem in an electrical
circuit. Verify that all connections in the circuit are clean and secure,
and that all connections are in good condition. If a problem with a con-
nection is found, correct the problem and verify that this diagnostic code
is Active before performing this procedure.
Perform open or short circuit test ateach harness connection to identify
correct harness to replace.
Perform this test only if condition is active.
Test Step 1. Verify if Code 0358-03
is Active.
1. Connect MSD (WP 0006). Select 0358-03 Code Active - Proceed to
Implement 120M and verify 0358- Test Step 2.
03 is active.
0358-03 Code Not Active -
Troubleshooting complete.
Test Step 2. Test for Shorted Cab
Lower Wiring Harness.
1. Turn ignition switch and battery
disconnect switch to the OFF
position.
2. Disconnect the hydraulic valve
wiring harness connector AP-C3
(WP 0009, Figure 215) from
implement pilot pressure supply
3. Disconnect the cab lower wiring
harness connector P-C39 (WP
0009, Figure 70) from implement
ECM J2 (WP 0009, Figure 71)
(WP 0268).
for continuity between cab lower
wiring harness connector P-C39
ECM (WP 0268).
(WP 0009, Figure 70) terminal 7
Connect the hydraulic valve wiring
and all other P-C39 terminals.
harness connector AP-C3 (WP 0009,
There should be no continuity.
Figure 215) to implement pilot
Figure 216).
Proceed to step 5.
0026-48