TM 5-3805-293-23-2
0026
Table 1. Implement Code (0041-03 to 0600-04) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
0296-12 Transmission
Resistance 5.0 Ohms or Less -
Control Abnormal Update
Proceed to step 11.
Rate - Continued
nector P-C41 (WP 0009, Figure
68) terminal 32 and machine
Replace cab lower wiring harness
ground.
(WP 0266).
Resistance should be less than
Proceed to step 15.
5.0 ohms.
Resistance 5.0 Ohms or Less -
Proceed to step 12.
nector P-C41 (WP 0009, Figure
68) terminal 56 and machine
Replace cab lower wiring harness
ground.
(WP 0266).
Resistance should be less than
Proceed to step 15.
5.0 ohms.
Resistance 5.0 Ohms or Less -
Proceed to step 13.
nector P-C41 (WP 0009, Figure
68) terminal 57 and machine
Replace cab lower wiring harness
ground.
(WP 0266).
Resistance should be less than
Proceed to step 15.
5.0 ohms.
Resistance 5.0 Ohms or Less -
Proceed to step 14.
nector P-C41 (WP 0009, Figure
68) terminal 70 and machine
Replace cab lower wiring harness
ground.
(WP 0266).
Resistance should be less than
Proceed to step 15.
5.0 ohms.
Resistance 5.0 Ohms or Less -
Proceed to Test Step 4.
nector P-C41 (WP 0009, Figure
68) terminal 13 and machine
Replace cab lower wiring harness
ground.
(WP 0266).
Resistance should be less than
Proceed to step 15.
5.0 ohms.
15. Using MSD (WP 0006), select
0296-12 Code Active - Repeat
Implement 120M and verify 0296- troubleshooting from the beginning of
12 is not active.
this diagnostic code.
0296-12 Code Not Active -
Troubleshooting complete.
Test Step 4. Test Cat Data Link Cir-
cuit from Cab Lower Wiring Har-
ness.
1. Turn ignition switch and battery
disconnect switch to the OFF
position (TM 5-3805-293-10).
0026-43