TM 5-3805-293-23-2
0026
Table 1. Implement Code (0041-03 to 0600-04) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
0358-03 Implement Pilot
for continuity between hydraulic
wiring harness (WP 0190).
Voltage Above Normal -
valve wiring harness connector
Connect the cab lower wiring harness
Continued
AP-C1 (WP 0009, Figure 213) ter-
connector P-C39 (WP 0009, Figure
minal 5 and all other AP-C1 termi-
70) to implement ECM J2 (WP 0009,
nals.
Figure 71) (WP 0268).
There should be no continuity.
Connect the rear chassis wiring
harness connector FA-C22 (WP 0009,
Figure 47) to cab lower wiring harness
connector P-C69 (WP 0009, Figure
46) (WP 0188).
Proceed to step 3.
wiring harness (WP 0188).
Connect the hydraulic valve wiring
harness connector AP-C3 (WP 0009,
Figure 215) to implement pilot
Figure 216).
Connect the cab lower wiring harness
connector P-C39 (WP 0009, Figure
70) to implement ECM J2 (WP 0009,
Figure 71) (WP 0268).
Proceed to step 3.
3. Using the MSD (WP 0006), select 0358-03 Code Active - Repeat
Implement 120M and verify 0358- troubleshooting code from the
03 is not active.
beginning.
0358-03 Code Not Active -
Troubleshooting complete.