TM 5-3805-293-23-2
0026
Table 1. Implement Code (0041-03 to 0600-04) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
0358-05 Implement Pilot
System Response:
Pressure Supply Solenoid
ECM will log a diagnostic code.
Current Below Normal
N OT E
Always inspect the harness connectorsthat are involved in the circuit.
Poor connections can often be the cause of a problem in an electrical
circuit. Verify that all connections in the circuit are clean and secure,
and that all connections are in good condition. If a problem with a con-
nection is found, correct the problem and verify that this diagnostic code
is Active before performing this procedure.
Perform open or short circuit test ateach harness connection to identify
correct harness to replace.
Perform this test only if condition is active.
Test Step 1. Verify if Code 0358-05
is Active.
1. Connect MSD (WP 0006). Select 0358-05 Code Active - Proceed to
Implement 120M and verify 0358- Test Step 2.
05 is active.
0358-05 Code Not Active -
Troubleshooting complete.
Test Step 2. Test for Faulty Imple-
ment Pilot Pressure Supply Sole-
noid.
1. Turn ignition switch and battery
disconnect switch to the OFF
position.
2. Disconnect the hydraulic valve
wiring harness connector AP-C3
(WP 0009, Figure 215) from
implement pilot pressure supply
3. Connect jumper wire between
hydraulic valve wiring harness
connector AP-C3 (WP 0009, Fig-
ure 215) terminal 1 and terminal
2.
0358-06 Code Active - Replace faulty
4. Using the MSD (WP 0006), select
implement pilot pressure supply
Implement 120M and check if
code 0358-06 becomes active.
Proceed to step 5.
0358-05 Code Remains Active-
Proceed to Test Step 3.
0026-51