TM 5-3805-261-10
TROUBLESHOOTING PROCEDURES - CONTINUED
0011 00
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
ELECTRICAL SYSTEM - CONTINUED
1. Check for blown fuses at fuse
If fuse is blown, request a
12. Defroster Fan Not Working (if Equipped).
replacement fuse from Unit
Maintenance. If fuse is okay, and
problem still exists, go to test step
2.
2. Check fan for disconnected
Reconnect electrical connectors
electrical connections.
if required. If problem still exists,
notify Unit Maintenance.
Check for blown fuse at fuse
If fuse is blown, request a
13. Heater Fan Not Working (if Equipped).
replacement from Unit
Maintenance. If fuse is okay,
notify Unit Maintenance.
ENGINE
1.
Engine Cranks but Fails to Start
(Operating Temperature Above 32F
[0C]).
WARNING
DO NOT perform fuel system checks, inspections, or mainte-
nance while smoking or near fire, flames, or sparks. Fuel may
ignite, causing damage to machine and injury or death to per-
sonnel.
Operating personnel must wear fuel-resistant gloves when
handling fuels. If exposed to fuel, promptly wash exposed skin
and change fuel-soaked clothing.
Check fuel level using fuel tank
If indication is empty, add fuel
dipstick.
okay, notify Unit Maintenance.