TM 5-3805-261-10
TROUBLESHOOTING PROCEDURES - CONTINUED
0011 00
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
ELECTRICAL SYSTEM - CONTINUED
1. Ensure STOP LIGHT or SER
Select STOP LIGHT or SER
4.
Front Work Lights Inoperative.
DRIVE function has been
DRIVE. If problem still exists, go
selected on military light
to test step 2.
switch.
2. Check for blown fuse at fuse
If fuse is blown, request a
replacement fuse from Unit
Maintenance. If fuse is okay, go
to test step 3.
3. Check light for separated
Reconnect connector, if required.
connection or damage.
If connector is okay, notify Unit
Maintenance.
1. Ensure STOP LIGHT or SER
Select STOP LIGHT or SER
5.
Directional Turn Signal or Hazard Flasher
DRIVE function has been
DRIVE. If problem still exists, go
Control Is Not Working.
selected on military light
to test step 2.
switch.
2. Check for blown fuse at fuse
If fuse is blown, request a
replacement fuse from Unit
Maintenance. If fuse is okay, go
to test step 3.
3. Check lights for separated
Reconnect connectors, if
connections or damage.
required. If any damage to lights
is found, notify Unit
Maintenance. If connectors and
lights are okay, notify Unit
Maintenance.
1. Ensure STOP LIGHT or SER.
Select STOP LIGHT or SER
6.
Horn Will Not Sound When Button Is
DRIVE function has been
DRIVE. If problem still exists, go
Pressed.
selected on military light
to test step 2.
switch.
2. Check for blown fuse at fuse
If fuse is blown, request a
replacement fuse from Unit
Maintenance. If fuse is okay and
problem still exists, go to test step
3.
3. Check horn for separated
Reconnect connectors, if
connections or damage.
required. If connectors are okay,
notify Unit Maintenance.