TM 5-3805-261-10
TROUBLESHOOTING PROCEDURES - CONTINUED
0011 00
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
ENGINE - CONTINUED
2.
Engine Cranks but Fails to Start
(Operating Temperature Below 32F
[0C]).
WARNING
DO NOT perform fuel system checks, inspections, or mainte-
nance while smoking or near fire, flames, or sparks. Fuel may
ignite, causing damage to machine and injury or death to per-
sonnel.
Operating personnel must wear fuel-resistant gloves when
handling fuels. If exposed to fuel, promptly wash exposed skin
and change fuel-soaked clothing.
1. Check fuel level using fuel
If indication is empty, add fuel
tank dipstick.
okay, go to test step 2.
NOTE
For every 30 seconds of engine cranking, allow 2 minutes for
starter motor to cool down.
If engine still will not start, notify
2. While cranking engine, press
ether starting aid switch. Wait
Unit Maintenance.
approximately 2 seconds
between injections.
Check air filter service indicator.
If indicator is red, service air filter
3.
Engine Does Not Develop Full Power.
problem still exists, notify Unit
Maintenance.
Check air filter service indicator.
If indicator is red, service air filter
4.
Engine Does Not Idle Properly.
problem still exists, notify Unit
Maintenance.