TM 5-3805-261-10
TROUBLESHOOTING PROCEDURES - CONTINUED
0011 00
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
EMS FAULT INDICATORS - CONTINUED
1. Check the battery cable
If corrosion is present, notify Unit
5.
connections for corrosion.
Maintenance. If no corrosion is
Operation.
present, go to test step 2.
If connections are loose, notify
2. Check the battery cable
connections for secure
Unit Maintenance. If connections
connections.
are not loose, go to test step 3.
damage and/or 1/2 in.
or more of deflection and/or is
deflection at mid-point of belt
damaged, notify Unit
on longest segment.
Maintenance. If belt is okay, go to
test step 4.
4. Inspect wiring harnesses and
If a wiring harness fault is found,
ground connections.
notify Unit Maintenance. If
problem still exists, notify Unit
Maintenance.
FAN PULLEY
ALTERNATOR
PULLEY
0.5 IN.
MAXIMUM
TRANSMISSION
PUMP
PULLEY
397-1098
Check fuel level in fuel tank.
6.
EMS Fuel Level Indicator Flashes During
00). If
indicator still flashes,
Operation.
notify Unit Maintenance.