TM 5-3805-293-23-2
0042
TEST 2 POSITIVE BATTERY CABLE CONTINUED
00042
6. Using digital multimeter, measure voltage between breaker panel positive junction point (Figure 11, Item 2) and
machine ground (Figure 11, Item 1). Voltage should not be less than 1 volt of value recorded in step 1.
a. If voltage is less than 1 volt of value recorded in step 1, replace positive battery cable (Figure 11, Item 3)
(WP 0195) between positive post of junction (Figure 11, Item 4) and breaker panel positive junction point
(Figure 11, Item 2). End of Task.
b. If voltage is equal to value recorded in step 1, proceed to step 7.
Figure 11. Breaker Panel Positive Junction Point.
0042