Figure 14. Fuel Prime Pump Harness Connector.
Figure 16. Fuel Prime Pump Relay and Inline Harness Connectors.

Maintenance Manual For Motorized Road Grader Model 120M - 2
Page Navigation
  1156    1157    1158    1159    1160  1161  1162    1163    1164    1165    1166  
img
.
TM 5-3805-293-23-2
0035
FUEL TRANSFER PUMP TEST CONTINUED
00035
14. Turn ignition switch and battery disconnect switch to the OFF position.
15. Remove tiedown strap (Figure 15, Item 6) from harness connector FE-C1 (Figure 15, Item 1). Discard tiedown
strap.
16. Disconnect harness connector FA-C18 (Figure 15, Item 5) from harness connector FE-C1 (Figure 15, Item 1).
17. Using a digital multimeter, test fuel prime pump ground circuit 229-BK for continuity between harness
connector FE-C1 terminal 1 (Figure 15, Item 3) and fuel prime pump harness connector FE-C4 terminal 2
(Figure 15, Item 2).
a. Continuity - Proceed to step 18.
b. No Continuity- Fuel prime pump ground circuit 229-BK is open between harness connector FE-C1 fuel and
prime pump harness connector FE-C4. Replace fuel wiring harness (WP 0064).
18. Using a digital multimeter, test fuel prime pump ground circuit 229-BK for continuity between harness
connector FA-C18 terminal 1 (Figure 15, Item 4) and ground.
No Continuity- Fuel prime pump ground circuit 229-BK is open between harness connector FA-C18 and
ground. Replace fuel wiring harness (WP 0188).
Figure 15. Fuel Pump Harness Inline Connector.
0035
0035-17