TM 5-3805-293-23-2
0027
Table 1. Implement Code (0615-02 TO 2113-04) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
1326-02 Implement 2 ECM
2. Disconnect cab lower wiring har-
Location Code Data Erratic,
ness connector P-C45 (WP 0009,
Intermittent or Incorrect -
Figure 72) from implement 2 ECM
Continued
(WP 0009, Figure 71) (WP 0268).
Resistance 5.0 Ohms or Less -
Proceed to step 4.
nector P-C45 (WP 0009, Figure
72) terminal 13 and machine
Proceed to Test Step 3.
ground.
Resistance should be less than
5.0 ohms.
Resistance 5.0 Ohms or Less -
Proceed to step 5.
nector P-C45 (WP 0009, Figure
72) terminal 23 and machine
Proceed to Test Step 3.
ground.
Resistance should be less than
5.0 ohms.
Resistance 5.0 Ohms or Less -
Proceed to step 6.
nector P-C45 (WP 0009, Figure
72) terminal 26 and machine
Proceed to Test Step 3.
ground.
Resistance should be less than
5.0 ohms.
Resistance 5.0 Ohms or Less -
Proceed to step 7.
nector P-C45 (WP 0009, Figure
72) terminal 27 and machine
Proceed to Test Step 3.
ground.
Resistance should be less than
5.0 ohms.
Resistance 5.0 Ohms or Less -
Proceed to step 8.
nector P-C45 (WP 0009, Figure
72) terminal 32 and machine
Proceed to Test Step 3.
ground.
Resistance should be less than
5.0 ohms.
Resistance 5.0 Ohms Or Less -
Proceed to step 9.
nector P-C45 (WP 0009, Figure
72) terminal 56 and machine
Proceed to Test Step 3.
ground.
Resistance should be less than
5.0 ohms.
0027-46