TM 5-3805-293-23-2
0027
Table 1. Implement Code (0615-02 TO 2113-04) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
0615-03 Machine Articula-
Test Step 2. Inspect Sensor and
tion Angle Sensor Voltage
Linkage.
Above Normal - Continued
1. Inspect articulation angle position
sensor 1 (left) (WP 0009, Figure
145) and linkage for the following:
a. Linkage securely connected
Linkage Loose or Sensor Not
to machine and to sensor.
Secure - Perform installation and
adjustment procedure for articulation
angle position sensor 1 (left) (WP
0257).
Proceed to step 2.
b. Remove articulation angle
Sensor Damaged - Replace
position sensor 1 (left) and
articulation angle position sensor 1
visually inspect sensor hous-
(left) (WP 0257).
ing, and harness connector
Proceed to step 2.
for damage (WP 0257).
c.
Linkage bent or damaged.
Linkage Bent or Damaged - Replace
articulation angle position sensor 1
(left) linkage and perform adjustment
(WP 0257).
Proceed to step 2.
Sensor and Linkage OK - Proceed to
Test Step 3.
2. Using MSD (WP 0006), verify
0615-03 Code Active - Proceed to
0615-03 is active for the transmis-
Test Step 3.
sion ECM or the Implement 1
0615-03 Code Not Active -
ECM.
Troubleshooting complete.
Test Step 3. Check 8 Volt Supply
Circuit From The Implement 1 ECM.
1. Turn ignition switch and battery
disconnect switch to the OFF
position (TM 5-3805-293-10).
2. Disconnect secondary steering
harness connector AT-C3 (WP
0009, Figure 144) from left articu-
lation angle position sensor (WP
0009, Figure 145) (WP 0257).
3. Turn battery disconnect switch
and ignition switch to the ON posi-
tion (TM 5-3805-293-10).
0027-13