TM 5-3805-293-23-2
0026
Table 1. Implement Code (0041-03 to 0600-04) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
0358-06 Implement Pilot
Test Step 3. Test for Shorted Cab
Pressure Supply Solenoid
Lower Wiring Harness.
Current Above Normal -
1. Turn ignition switch and battery
Continued
disconnect switch to the OFF
position.
2. Disconnect the cab lower wiring
harness connector P-C39 (WP
0009, Figure 70) from implement
ECM J2 (WP 0009, Figure 71)
(WP 0268).
for continuity between cab lower
No Continuity- Replace implement 1
wiring harness connector P-C39
ECM (WP 0268).
(WP 0009, Figure 70) terminal 7
Connect the hydraulic valve wiring
and terminal 8.
harness connector AP-C3 (WP 0009,
There should be no continuity.
Figure 215) to implement pilot
Figure 216).
Proceed to step 4.
4. Using the MSD (WP 0006), select 0358-06 Code Active - Repeat
Implement 120M and verify 0358- troubleshooting code from the
06 is not active.
beginning.
0358-06 Code Not Active -
Troubleshooting complete.
Test Step 4. Test for Shorted Rear
Chassis Wiring Harness.
1. Disconnect the rear chassis wir-
ing harness connector FA-C22
(WP 0009, Figure 47) from cab
lower wiring harness connector P-
C69 (WP 0009, Figure 46) (WP
0188).
for continuity between rear chas-
No Continuity- Replace cab lower
sis wiring harness connector FA-
wiring harness (WP 0266).
C22 (WP 0009, Figure 47) termi-
Connect the hydraulic valve wiring
nal 31 and terminal 32.
harness connector AP-C3 (WP 0009,
There should be no continuity.
Figure 215) to implement pilot
Figure 216).
Proceed to step 3.
0026-56