TM 5-3805-261-23-1
ELECTRICAL SYSTEM TROUBLESHOOTING PROCEDURES - CONTINUED
0008 00
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
9.
Test for continuity between starter
5.
Starting Motor Is Inoperative
relay ground wire and chassis
- Continued.
ground.
a. Place battery disconnect switch in
OFF position.
b. Connect meter positive lead to
ground wire for relay (harness
side).
c. Connect meter negative lead to
1. If continuity is indicated, go to Test 10.
chassis ground and observe
reading.
still exists, go to Test 2.
397-2428
a. Place battery disconnect switch in
OFF position.
b. Disconnect both larger gauge wires
from starter relay.
0008 00-11