TM 5-3805-261-23-1
ELECTRICAL SYSTEM TROUBLESHOOTING PROCEDURES - CONTINUED
0008 00
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4.
Perform voltage drop test on starting
6.
Solenoid and Starting Motor
motor-to-solenoid connector.
Operate; Engine Cranks
Slowly - Continued.
a. Connect meter negative lead to
positive terminal on starting motor
and meter positive lead to MTR
terminal on solenoid.
b. Crank engine and observe meter.
If voltage reading exceeds 0.1 volt, place
battery disconnect switch in OFF position
and clean and tighten starting motor-to-
solenoid connections. Replace if broken.
If the problem still exists, go to Test 5.
G
S
MTR
(+)
(-)
BAT
397-2431
5.
Perform voltage drop test on solenoid
contactors.
a. Connect meter positive lead to
negative lead to solenoid MTR
terminal.