TM 5-3805-261-23-1
ELECTRICAL SYSTEM TROUBLESHOOTING PROCEDURES - CONTINUED
0008 00
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
e. Momentarily turn start switch fully
1. If voltage is indicated, go to Test 8.
5.
Starting Motor Is Inoperative
to the right and observe meter.
- Continued.
2. If voltage is not indicated, place battery
disconnect switch in OFF position,
reconnect white wire and go to Test 11.
397-2426
8.
Test for voltage between starter relay
and chassis ground.
a. Place battery disconnect switch in
OFF position.
b. Disconnect ground from starter
c. Connect meter positive lead to
ground terminal on relay (relay
side).
d. Connect meter negative lead to
chassis ground.
0008 00-9