TM 5-3805-261-23-1
ELECTRICAL SYSTEM TROUBLESHOOTING PROCEDURES - CONTINUED
0008 00
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
f. Momentarily turn start switch fully
1. If voltage is indicated, go to Test 6.
5.
Starting Motor Is Inoperative
to the right and observe meter
- Continued.
2. If voltage is not indicated, go to Test 7.
reading.
S
G
MTR
(+)
(-)
V
BAT
397-2424
6.
ground.
a. Place battery disconnect switch in
OFF position.
b. Connect meter positive lead to G
0008 00-7