TM 5-3805-261-23-1
ELECTRICAL SYSTEM TROUBLESHOOTING PROCEDURES - CONTINUED
0008 00
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
6.
voltage range.
Operate; Engine Cranks
Slowly - Continued.
b. Connect meter positive lead to
positive terminal on starting motor
and negative meter lead to chassis
ground.
MTR
G
S
(+)
(-)
BAT
397-2430
c. Crank engine and observe voltage
1. If voltage is low, place battery
reading on meter. Voltage should
disconnect switch in OFF position and
exceed 22 volts.
clean and tighten starting motor
terminal connections. If problem still
exists, go to Test 4.
0008 00-14