TM 5-3805-261-23-1
ELECTRICAL GENERAL MAINTENANCE INSTRUCTIONS
THIS WORK PACKAGE COVERS
Military Connector Repair
Cleaning and Inspection
Ring Terminal Repair
Multiple-Pin Connector Identification Diagrams
Connector Repair
Splicing Wires
Electrical Ground Points
Sealed Connector Repair
Receptacle Connector Repair
Relay Inspection and Test
Waterproof Connector Repair
INITIAL SETUP
Maintenance Level
Materials/Parts - Continued
Unit
Grease, electrically conductive (Item 18, WP 0349
Tools and Special Tools
Shop equipment, common no. 1 (Item 75, WP 0348
Materials/Parts
References
NOTE
Use electrically conductive grease on unprotected (exposed to weather) electrical connectors before
connections are made.
Use electrical insulating varnish on all electrical connections that are mounted outside of machine and
are exposed to harsh weather and/or road spray.
CLEANING AND INSPECTION
0021 00
CAUTION
Washing electrical wires with solvent cleaning compounds or mineral spirits will cause serious damage or
destroy the material.
1.
Wash electrical wires with a mild solution of detergent and water and wipe dry.
2.
Inspect electrical wires and repair if necessary as specified below.
3.
Inspect all other components in accordance with WP 0020 00.