TM 5-3805-293-23-2
0042
TEST 2 POSITIVE BATTERY CABLE CONTINUED
00042
7. Using digital multimeter, measure voltage between alternator positive cable (Figure 12, Item 2) and machine
ground (Figure 12, Item 1). Voltage should not be less than 1 volt of value recorded in step 1.
a. If voltage is less than 1 volt of value recorded in step 1, replace alternator positive cable (Figure 12, Item 3)
(WP 0066). End of Task.
b. If voltage is equal to value recorded in step 1, proceed to step 8.
0042