TM 5-3805-293-23-2
0042
TEST 2 POSITIVE BATTERY CABLE CONTINUED
00042
8. Using digital multimeter, measure voltage between arctic heater positive battery cable junction point (Figure
13, Item 3) and machine ground (Figure 13, Item 2). Voltage should not be less than 1 volt of value recorded in
step 1.
a. If voltage is less than 1 volt of value recorded in step 1, replace arctic heater interior positive battery cable
(Figure 13, Item 1) (WP 0338). End of Task.
b. If voltage is equal to value recorded in step 1, proceed to Test 3.
Figure 13. Arctic Heater Positive Battery Cable Junction Point.
0042
END OF TASK