TM 5-3805-261-34
STARTING SYSTEM MAINTENANCE.
4-12.
Starting Motor (Bosch). (Sheet 7 of 11)
CLEANING
2.
Remove loose particles from
armature (43, Figure 4-82) with
compressed air and wipe with a
clean cloth dampened with dry
cleaning solvent. Clean commuta-
tor lightly with No. 00 Grit
sandpaper and remove all traces
of dust with low pressure
compressed air.
INSPECTION
Inspect all parts. Refer to Chapter 2.
ASSEMBLY
1.
Install bushing (54) on field
coil (51, Figure 4-80) pin
terminal.
2.
Position four pole shoes (52) in
field coil (51) the same way as
marked.
NOTE
Careful installation of the
field coil is necessary to
prevent shorting or grounding
of the field coil as pole
shoes are tightened into
place.
3.
Using pole shoe spreader, install
field coil (51) in housing (53).
Pull pin terminal through bore of
housing (53).
4.
Install eight screws (50) and
tighten to 42 ft-lb torque.
Go to Sheet 8
4-71
Figure 4-82.
Figure 4-80.