TM 5-3805-261-34
STARTING SYSTEM MAINTENANCE.
4-12.
Starting Motor (Bosch). (Sheet 3 of 11)
DISASSEMBLY
9.
Remove bushing (17) from terminal
stud (22,Figure 4-73).
10.
Remove four screws (18).
11.
Disconnect four brushes (19) wire
assemblies.
12.
Disconnect two field coil (51)
wire assemblies.
13.
Lift four springs (20) with
suitable hook to remove four
brushes (19).
14.
Remove four brushes (19).
15.
Remove four springs (20).
16.
Remove two screws (21) and
terminal stud (22).
NOTE
The following procedure is
Figure 4-73.
for the removal of one screw.
Repeat steps 19 thru 21 for
the removal of the remaining
three screws.
17.
Install two M5X0.8 hex nuts on
screw (23).
18.
Using suitable wrench to turn
inside nut of two M5X0.8 hex
nuts, remove screw (23) from
plate assembly (24).
19.
Remove two M5X0.8 hex nuts from
screw (23).
20.
Remove plate assembly (24) from
housing (53).
21.
Remove and discard preformed
packing (25) from housing (53).
4-67