TM 5-3805-261-34STARTING SYSTEM MAINTENANCE.4-12.StartingMotor(Bosch). (Sheet 3 of 11)DISASSEMBLY9.Remove bushing (17) from terminalstud (22,Figure 4-73).10.Remove four screws (18).11.Disconnect four brushes (19) wireassemblies.12.Disconnect two field coil (51)wire assemblies.13.Lift four springs (20) withsuitable hook to remove fourbrushes (19).14.Remove four brushes (19).15.Remove four springs (20).16.Remove two screws (21) andterminal stud (22).NOTEThe following procedure isFigure 4-73.for the removal of one screw.Repeat steps 19 thru 21 forthe removal of the remainingthree screws.17.Install two M5X0.8 hex nuts onscrew (23).18.Using suitable wrench to turninside nut of two M5X0.8 hexnuts, remove screw (23) fromplate assembly (24).19.Remove two M5X0.8 hex nuts fromscrew (23).20.Remove plate assembly (24) fromhousing (53).21.Remove and discard preformedpacking (25) from housing (53).4-67