TM 5-3805-261-34STARTING SYSTEM MAINTENANCE.4-12.StartingMotor(Bosch). (Sheet 5 of 11)DISASSEMBLY32.Remove armature (43) from housing(53, Figure 4-79).33.Remove nut (44), lockwasher (45),washers (46 and 47), insulator(48) and seal (49) from fieldcoil (51, Figure 4-80) pinterminal. Discard seal (49).NOTEPositions of pole shoes inhousing must be marked to aidin proper assembly.34.Remove eight screws (50).35.Remove field coil (51) and fourpole shoes (52) from housing(53).36.Remove bushing (54) from fieldcoil (51) pin terminal.CLEANING1.Clean four brushes (19) with adry cloth only. Do not permitdry cleaning solvent to come incontact with four brushes (19,Figure 4-81).Figure 4-81.Go to Sheet 64-69Figure 4-79.Figure 4-80.