TM 5-3805-261-23-1
ELECTRICAL SYSTEM TROUBLESHOOTING PROCEDURES - CONTINUED
0008 00
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
d. Crank engine and observe meter.
If voltage exceeds 0.4 volt, clean and
6.
tighten cable connections at batteries,
Operate; Engine Cranks
starting motor, and chassis ground points.
Slowly - Continued.
If the problem still exists, go to Test 7.
G
S
MTR
(+)
(-)
BAT
397-2433
7.
Test positive cable voltage from
batteries to solenoid.
a. Place battery disconnect switch in
OFF position.
b. Connect meter positive lead to
battery positive terminal and meter
terminal.
c. Place battery disconnect switch to
ON position.
0008 00-17