BRAKE ACCUMULATOR SERVICE TEST AND CHARGE CONTINUED
46. Turn valve (Figure 62, Item 3) fully counterclockwise.
47. Disconnect valve nut (Figure 62, Item 2) from right accumulator (Figure 62, Item 1).
48. Apply soapy water solution to right accumulator (Figure 62, Item 1) charge port.
a. If bubbles are observed, discharge accumulator and replace accumulator valve (WP 0264).
b. If no bubbles appear, proceed to step 49.
Figure 62. Right Accumulator and Valve.
0044
49. Install caps (Figure 63, Item 2) on left and right accumulator (Figure 63, Item 1).
Figure 63. Cap.
0044