Figure 61. Nitrogen Bottle Venting.
Figure 64. Nitrogen Charge Group.

Maintenance Manual For Motorized Road Grader Model 120M - 3
Page Navigation
  158    159    160    161    162  163  164    165    166    167    168  
img
.
TM 5-3805-293-23-3
0044
BRAKE ACCUMULATOR SERVICE TEST AND CHARGE CONTINUED
46. Turn valve (Figure 62, Item 3) fully counterclockwise.
47. Disconnect valve nut (Figure 62, Item 2) from right accumulator (Figure 62, Item 1).
48. Apply soapy water solution to right accumulator (Figure 62, Item 1) charge port.
a. If bubbles are observed, discharge accumulator and replace accumulator valve (WP 0264).
b. If no bubbles appear, proceed to step 49.
Figure 62. Right Accumulator and Valve.
0044
49. Install caps (Figure 63, Item 2) on left and right accumulator (Figure 63, Item 1).
Figure 63. Cap.
0044