Figure 53. Regulator and Nitrogen Bottle.
Figure 57. Right Accumulator and Valve.

Maintenance Manual For Motorized Road Grader Model 120M - 3
Page Navigation
  154    155    156    157    158  159  160    161    162    163    164  
img
.
TM 5-3805-293-23-3
0044
BRAKE ACCUMULATOR SERVICE TEST AND CHARGE CONTINUED
26. Close nitrogen cylinder valve (Figure 55, Item 3) on nitrogen cylinder (Figure 55, Item 5).
27. Turn vent valve (Figure 55, Item 1) counterclockwise to bleed off pressure until gauge on left (Figure 55,
Item 2) indicates 0 psi (0 kPa).
28. Turn vent valve (Figure 55, Item 1) clockwise to close valve.
29. Disconnect regulator nut (Figure 55, Item 3) from nitrogen release valve (Figure 55, Item 4).
Figure 55. Nitrogen Bottle Venting.
0044
30. Turn valve (Figure 56, Item 3) fully counterclockwise.
31. Disconnect valve nut (Figure 56, Item 2) from left accumulator (Figure 56, Item 1).
Figure 56. Left Accumulator and Valve.
0044
0044-42