BRAKE ACCUMULATOR SERVICE TEST AND CHARGE CONTINUED
32. Apply soapy water solution to left accumulator (Figure 56, Item 1) charge port.
a. If bubbles are observed, discharge accumulator and replace accumulator valve (WP 0264).
b. If no bubbles appear, proceed to step 33.
33. Connect valve nut (Figure 57, Item 2) to right accumulator (Figure 57, Item 1).
34. Turn valve (Figure 57, Item 3) fully clockwise.
Figure 57. Right Accumulator and Valve.
0044
35. If pressure gauge (Figure 58, Item 1) indicates that pressure in accumulator is low, compared to pressure indi-
cated in Table 1, then proceed as follows. Otherwise, proceed to step 41.
Figure 58. Pressure Gauge.
0044