FLYWHEEL, FLYWHEEL HOUSING AND GEAR GROUP INSPECT CONTINUED
Flywheel Runout
00032
1. Mount dial indicator on face of flywheel housing.
2. Position dial indicator on inside radius of flywheel face of flywheel (Figure 23, Item 1). Set pointer of dial
indicator to 0 inch (0 mm).
3. Turn flywheel. Note reading on dial indicator every 45 degrees.
a. Calculate difference between lowest measurement and highest measurement of four locations.
b. Difference must not be greater than 0.012 in. (0.30 mm). If greater than 0.012 in. (0.30 mm) replace engine
(WP 0069).