TM 5-3805-293-23-2
0031
Table 1. Implement Code (2200-00 TO 2954-14) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2210-03 Auxiliary Lever #7
Resistance 5.0 Ohms or Less -
Position Sensor Voltage
continuity between harness con-
Proceed to step 4.
Above Normal - Continued
nector P-C33 (WP 0009, Figure
209) terminal 3 and harness con-
Replace cab lower wiring harness
nector P-C27 (WP 0009, Figure
(WP 0266).
74) terminal 26.
Proceed to step 5.
5.0 Ohms.
continuity between harness con-
harness (WP 0266).
nector P-C27 (WP 0009, Figure
Proceed to step 5.
74) terminal 26 and all other ter-
minals on harness connector P-
lever (WP 0275).
C27.
Connect harness connector P-C27
There should be no continuity.
(WP 0009, Figure 74) to implement
ECM J2 (WP 0009, Figure 75) (WP
0268).
Connect cab lower harness connector
P-C41 (WP 0009, Figure 69) to
implement 1 ECM J1 (WP 0009,
Figure 68) (WP 0268).
Proceed to step 5.
5. Using the MSD (WP 0006), select 2210-03 Code Active - Repeat
Implement 120M and verify 2210- troubleshooting code from the
03 is not active.
beginning.
2210-03 Code Not Active -
Troubleshooting complete.
0031-102