TM 5-3805-293-23-2
0031
Table 1. Implement Code (2200-00 TO 2954-14) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2210-04 Auxiliary Lever #7
Position Sensor Voltage
continuity between harness con-
harness (WP 0266).
Below Normal - Continued
nector P-C27 (WP 0009, Figure
Proceed to step 6.
74) terminal 26 and all other ter-
minals on harness connector P-
ECM (WP 0268).
C27 and to machine ground.
Connect cab lower harness connector
There should be no continuity.
P-C33 (WP 0009, Figure 209) to
scarifier lever (WP 0009, Figure 210)
(WP 0275).
Proceed to step 6.
6. Using the MSD (WP 0006), select 2210-04 Code Active - Repeat
Implement 120M and verify 2210- troubleshooting code from the
04 is not active.
beginning.
2210-04 Code Not Active -
Troubleshooting complete.
2210-08 Auxiliary Lever #7
System Response:
Position Sensor Abnormal
ECM will log a diagnostic code.
Period
N OT E
Always inspect the harness connectorsthat are involved in the circuit.
Poor connections can often be the cause of a problem in an electrical
circuit. Verify that all connections in the circuit are clean and secure,
and that all connections are in good condition. If a problem with a con-
nection is found, correct the problem and verify that this diagnostic code
is Active before performing this procedure.
Perform open or short circuit test ateach harness connection to identify
correct harness to replace.
Perform this test only if condition is Active.
Test Step 1. Verify 2210-08 code is
active.
1. Connect MSD (WP 0006), select
2210-08 Code Active - Proceed to
Implement 120M and check for
Test Step 2.
Active code 2210-08.
2210-08 Code Not Active -
Troubleshooting complete.
Test Step 2. Test Implement ECM
And Scarifier Lever.
1. Disconnect cab lower harness
connector P-C33 (WP 0009, Fig-
ure 209) from scarifier lever (WP
0009, Figure 210) (WP 0275).
0031-104