TM 5-3805-293-23-2
0031
Table 1. Implement Code (2200-00 TO 2954-14) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2211-03 Auxiliary Valve #1
Test Step 3. Test Cab Lower Wiring
Harness.
Above Normal - Continued
1. Disconnect front attachment har-
ness connector U-C1 (WP 0009,
Figure 121) from cab lower har-
ness connector P-C50 (WP 0009,
Figure 120).
continuity between harness con-
harness (WP 0266).
nector P-C45 (WP 0009, Figure
Connect front attachment harness
72) terminal 59 and all other ter-
connector U-C15 (WP 0009, Figure
minals on harness connector P-
246) to auxiliary valve #1 port a
C45.
There should be no continuity.
Figure 247), and install front frame
nose cover (WP 0224).
Proceed to step 3.
attachment wiring harness (WP
0180).
Connect cab lower harness connector
P-C45 (WP 0009, Figure 72) to
implement 2 ECM J1 (WP 0009,
Figure 73).
Proceed to step 3.
3. Using MSD (WP 0006), select
2211-03 Code Active - Repeat
Implement 120M and verify 2211-
troubleshooting code from the
03 is active.
beginning.
2211-03 Code Not Active -
Troubleshooting complete.
0031-107