Table 1. Implement Code (2200-00 TO 2954-14) Troubleshooting Procedures - Continued.
Table 1. Implement Code (2200-00 TO 2954-14) Troubleshooting Procedures - Continued.

Maintenance Manual For Motorized Road Grader Model 120M - 2
Page Navigation
  992    993    994    995    996  997  998    999    1000    1001    1002  
img
TM 5-3805-293-23-2
0031
Table 1. Implement Code (2200-00 TO 2954-14) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2203-03 Steering Valve Con-
6. Using digital multimeter, test for
Resistance 5.0 Ohms or Less -
trol Module Spool Position
continuity between harness con-
Proceed to step 7.
Signal Lines Voltage Above
nector U-C1 (WP 0009, Figure
Resistance More Than 5.0 Ohms -
Normal - Continued
121) terminal 25 and terminal 60.
Replace front attachment wiring
Resistance should be less than
harness (WP 0180).
5.0 Ohms.
Proceed to step 13.
7. Remove jumper wire from har-
ness connector U-C11 (WP 0009,
Figure 256) terminal 1 and termi-
nal 2.
8. Install a jumper wire between har-
ness connector U-C34 (WP 0009,
Figure 217) terminal 1, and termi-
nal 6.
9. Using digital multimeter, test for
Resistance 5.0 Ohms or Less -
continuity between harness con-
Proceed to step 10.
nector U-C1 (WP 0009, Figure
Resistance More Than 5.0 Ohms -
121) terminal 25 and terminal 60.
Replace front attachment wiring
Resistance should be less than
harness (WP 0180).
5.0 Ohms.
Proceed to step 13.
10. Remove jumper wire from har-
ness connector U-C34 (WP 0009,
Figure 217) terminal 1, and termi-
nal 6.
11. Using digital multimeter, test for
Continuity - Replace front
continuity between harness con-
attachment wiring harness (WP
nector U-C1 (WP 0009, Figure
0180).
121) terminal 25 and all other ter-
Proceed to step 13.
minals on harness connector U-
No Continuity - Proceed to step 12.
C1 and to machine ground.
There should be no continuity.
12. Using digital multimeter, test for
Continuity - Replace front
continuity between harness con-
attachment wiring harness (WP
nector U-C1 (WP 0009, Figure
0180).
121) terminal 60 and all other ter-
Proceed to step 13.
minals on harness connector U-
No Continuity - Proceed to Test Step
C1 and to machine ground.
3.
There should be no continuity.
13. Using the MSD (WP 0006), select  2203-03 Code Active - Repeat
Implement 120M and verify 2203- troubleshooting code from the
03 is not active.
beginning.
2203-03 Code Not Active -
Troubleshooting complete.
0031-90