TM 5-3805-293-23-2
0026
Table 1. Implement Code (0041-03 to 0600-04) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
0490-04 Implement Lock Out
5. Using the MSD (WP 0006), select 0490-04 Code Active - Repeat
Switch Voltage Below
Implement 120M and verify 0490- troubleshooting code from the
Normal - Continued
04 is not active.
beginning.
0490-04 Code Not Active -
Troubleshooting complete.
Test Step 3. Test for Open Cab
Lower Wiring Harness.
1. Disconnect the cab lower wiring
harness connector P-C39 (WP
0009, Figure 70) from implement
ECM J2 (WP 0009, Figure 71)
(WP 0268).
2. Disconnect the cab lower wiring
harness connector P-C41 (WP
0009, Figure 68) from implement
ECM J1 (WP 0009, Figure 69)
(WP 0268).
3. Connect jumper wire between cab
lower wiring harness connector P-
C94 (WP 0009, Figure 207) termi-
nal 4 and terminal 5.
for resistance between cab lower
Proceed to step 5.
wiring harness connector P-C39
(WP 0009, Figure 70) terminal 1
Replace cab lower wiring harness
and P-C41 (WP 0009, Figure 68)
(WP 0266).
terminal 31.
Proceed to step 8.
Resistance should be 5.0 ohms or
less.
5. Remove jumper wire between cab
lower wiring harness connector P-
C94 (WP 0009, Figure 207) termi-
nal 4 and terminal 5.
6. Connect jumper wire between cab
lower wiring harness connector P-
C94 (WP 0009, Figure 207) termi-
nal 5 and terminal 6.
for resistance between cab lower
Replace implement 1 ECM (WP
wiring harness connector P-C41
0268).
(WP 0009, Figure 68) terminal 31
Proceed to step 8.
and terminal 14.
Resistance should be 5.0 ohms or
Replace cab lower wiring harness
less.
(WP 0266).
Proceed to step 8.
0026-61