TM 5-3805-261-34CHARGING SYSTEM MAINTENANCE. (cont)4-4.Alternator(Delco).(Sheet 18 of 18)ASSEMBLY (cont)NOTERotor may lose magnetism or a new rotor may needto be magnetized.58. Using 24 volt battery, magnetize rotor (57).Connect positive wire on stud (40) and negativewire to housing (80, Figure 4-18). Connect thirdjumper wire to the positive battery jumper wire.Momentarily touch the other end of the thirdjumper wire to stud (17). This will magnetizerotor (57).NOTEReturn 130G Grader to original equipment condition.Figure 4-18.Endof Task4-22