TM 5-3805-261-23-1
ELECTRICAL SYSTEM TROUBLESHOOTING PROCEDURES - CONTINUED
0008 00
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
Check blade float fuse (10A).
28. Blade Float Limit Switch
Does Not Operate (CCE
the problem still exists, go to Test 2.
Machine).
2.
switch. Connect one lead of
ground.
Check air pressure gauge for proper
Replace air pressure switch if damaged or
29. Air Pressure Switch Is Not
Operating.
reading (TM 5-3805-261-10).
1.
Check oil level in engine (TM 5-
30. Engine Oil Pressure Switch
3805-261-10).
Does Not Operate.
2.
Start engine and run for several
Replace engine oil pressure switch if oil
minutes.
pressure is not within operating range
1.
Check coolant level.
31. Coolant Temperature Switch
Does Not Operate.
2.
Start engine and run for several
Replace coolant temperature switch if
minutes.
temperature is not within operating range
Check fuel pressure with a pressure gauge
Replace fuel pressure switch if damaged
32. Fuel Pressure Switch Does
Not Operate.
of known accuracy installed in fuel line.
Start engine and run several minutes.
If the temperature remains within normal
33. Hydraulic Oil Temperature
Switch Does Not Operate.
Operate implements until hydraulic oil
range and the alarm still sounds, replace
temperature is at normal operating
hydraulic oil temperature switch (WP
temperature.
1.
Test continuity of hourmeter switch.
34. Hour Meter Does Not
Connect one lead of multimeter to
Operate.
switch and one lead to ground.
problem still exists, go to Test 2.
2.
Connect one lead of multimeter to
back of gauge and one lead to ground.
1.
Check windshield wiper fuse (4A).
35. Windshield Wipers Do Not
Operate (CCE Machine).
the problem still exists, go to Test 2.
2.
Test continuity of windshield wiper
switch. Connect one lead of
multimeter to back of switch and one
lead to ground.
1.
Check lamp.
36. Panel Lamp Does Not
Operate.
If the problem still exists, go to Test 2.