TM 5-3805-261-23-1
ELECTRICAL SYSTEM TROUBLESHOOTING PROCEDURES - CONTINUED
0008 00
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
c. Connect meter positive lead to
37. Engine Cranks, but Will Not
purple disconnected wire and meter
Start in Cold Weather (Fuel
negative lead to chassis ground.
Available) - Continued.
d. Crank engine, press starting aid
1. If voltage is indicated, replace starting
button and observe meter.
2. If voltage is not indicated, go to Test 6.
6.
Test temperature switch wire for
continuity.
a. Place battery disconnect switch in
OFF position.
b. Disconnect wire between starting
aid switch and starting aid valve at
both ends.
(Ω) range.
d. Connect meter positive lead to one
end of wire. Connect meter
negative lead to other end of wire.
1.
Test heater circuit voltage.
38. Heater Will Not Operate or
Will Not Operate in High
Speed or Low Speed Position
(CCE Machine).
a. Place battery disconnect switch in
OFF position.
b. Check heater fuse.
2. If fuse is not blown, reinstall fuse and
go to Step c.
c. Disconnect heater fan motors
wires.
voltage range.
e. Connect meter negative lead to
chassis ground.
f. Place battery disconnect switch in
ON position.